HT Enthusiast Extended Custom Workflow 22.0.0 - 1/8/2020
Requires CalMAN 2019 ver. 5.10.2.49.

DISCLAIMER: Use this software at your own risk. It is offered free of charge, as is, no guarantees. By downloading it you accept full responsibility for anything that may happen in your life afterwards because of, in spite of, or any other of, its use.

Click here to download workflow 22.0.0

HT Enthusiast Extended Workflow Features

► Navi, the Navigation bar on the right, provides access to selected context suitable layouts with easy to read and reach buttons.
► Clicking the Navi bar itself shows the Navigation Index layout, providing easy acces to every workflow layout and key CalMAN panels.
► Comprehensive Notes Management layout is always accessible from the Navi bottom.
► Integrated Session Setup layout with hardware configuration and dynamic range assessment, supported by Meter Profile Management, Meter Stability, and Screen Uniformity layouts.
► Comprehensive detailed calibration layouts with charts and datagrids for Two- & Multipoint Grayscale, Gamut Saturation and 3D Color Cube LUT.
► Single Pre- & PostCalibration layouts take all readings for Grayscale, Gamut Saturation, Gamut Luminance and Color Checker all with accesible charts, and datagrids for Post Grayscale and Gamut Saturation.
► High-count calibration points, HDR friendly with EOTF charts.
► DeltaE is DEITP, Compensated is default, With Luminance Error if indicated or after the "/".
► Compare Calibrations layout lets you compare three calibrations side by side.
► DEITP vs. De 2000 comparison layout to see both side by side, using PostCal or new readings.
► All DDC layout has all DDC controls in one place.

Image

What's new:
- Fixed a few things that weren't working as expected.
- Some tweaks, shown in these screens, otherwise same as 21.0.0:

Image Image Image Image Image Image

--------------------------------------------------------------------------
PREVIOUS VERSIONS
--------------------------------------------------------------------------
Previous version 21.0.0 - 10/26/2019
Requires CalMAN 2019 ver. 5.10.1.94.

- Created new from scratch base framework to best conform to new revisions.
- All-new completely revised navigation system.
- Removed Pre/Post-Calibration datagrids since the calibration datagrids should suffice, reducing unneeded bloat.
- Removed CMY ramps from the 3D LUT layoiut since they're not part of the LUT structure, only RGB are actually needed. - Some adjustments to deal with new basic core behavior.
- Various small fixes and tweaks.


Click here to download workflow 21.0.0
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 19.3.0 - 7/5/2019
Requires CalMAN 2019 ver. 5.10.0.50.

- Small update to the Session Setup layout and cleaned up two rogue labels over the Notes data.
- Some enhancements to the data in the All DDC layout showing all DDC panels together.
- Switched the data points control in the Multi-Point Calibration layout to another convenient Gray Levels control since it's really a setup aspect and it's already there.
- Various small fixes and tweaks.


Click here to download workflow 19.3.0
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 19.2.0 - 5/11/2019
Requires CalMAN 2019 ver. 5.10.0.50.

- New All DDC layout showing all DDC panels together, accessed from Session Setup or Final Check layouts.
- Various small fixes and tweaks.

Click here to download workflow 19.2.0
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 19.1.0 - 5/11/2019
Requires CalMAN 2019 R1 ver. 5.10.0.49.

- SpectraCal corrected the DEITP Collection Avg datafield bug and they have been restored to show the value instead of 0.
- Added large AutoCal button to all calibration layouts.
- The DDC/Display option in the MultiPoint Calibration layout is now automatically turned off during AutoCal.
- Switched the Luminance chart in the MultiPoint Calibration layout to bar mode reflecting actual Nits.
- New DEITP vs. De 2000 comparison layout to see both side by side, accessed from Post-Calibration readings layout, using Post-Cal or new readings.

Click here to download workflow 19.1.0
Click here to display or download screens as a PDF book

-------------------------------------

Previous version 18.2.3 - 2/25/2019; 19.0.1 - 3/3/2019
Requires CalMAN 2018 R3 5.9.2 for 18.2.3, CalMAN 2019 5.10.0.41 for 19.0.1.

19.0.1 is same as 18.2.3 but corrected to work with CalMAN 2019.
Due to a CalMAN 2019 bug the average DEITP with Luminance Error will show as 0 NA. Will correct that when CalMAN removes the bug, apparently in the next RC.

- Added a new Compare Calibrations layout that lets you check two calibrations side by side to help optimize base settings used to calibrate.
- Fixed several data sources in the Meter Profile Analysis layout that somehow got reset to default, preventing some values from being properly displayed.
- Reassigned all comparators to use DEITP instead of Delta-E 2000

Click here to download workflow 18.2.3
Click here to download workflow 19.0.1
Click here to display or download screens as a PDF book

-------------------------------------

Previous version 18.2.2
Requires CalMAN 2018 R3 5.9.2 or later.

- From 18.2.1 changed title of DeltaE from "ICtCp 720" to the new official title of DEITP in all layouts.

Click here to download workflow
Click here to display or download screens as a PDF book - same PDF as 18.2.1 so still says ICtCp 720

-------------------------------------

Previous version 18.2.1
Requires CalMAN 2018 R3 5.9.2 or later.

- Meter Stability layout: Added meter selection drobdown.
- Meter Profiling layout: Added chart refresh button to fix out of range readings, some sizing adjustments.
- The usual small fixes and visual tweaks.

Click here to download workflow
Click here to display or download screens as a PDF book

-------------------------------------

Previous version 18.2.0
Requires CalMAN 2018 R3 5.9.2 or later.

- Whole workflow: Converted every Delta E chart and datafield to the ICtCp 720 variant (the numbers may look higher but the image hopefully looks better :).
- Session Setup layout: Fixed possible lockout between DDC and Meter Profile panels, added Gamma or RGB chart option for initial setup check, some minor control field shuffling.
- Multipoint Grayscale layout: Relocated the Summary section, added an option to show the Display section of the DDC panel.
- The usual small fixes and visual tweaks here and there, and who knows what else ...

Click here to download workflow
Click here to display or download screens as a PDF book

-------------------------------------

Previous version 18.1.0
Requires CalMAN 2018 R2 or later.

- Significant redesign of the 2-Point and Multipoint Grayscale Calibration layouts.
- Significant redesign of the Meter Profile Analysis layout.
- The usual small fixes and visual tweaks here and there, and who knows what else ...

Click here to download workflow
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 18.0.1
Requires CalMAN 5 release 5.9.1 or later.

18.0.1 is the same as 18.0.0 (same PDF) with some minor fixes:
- Fixed the Multipoint Grayscale Calibration layout single point charts for Gamma (auto axis not selected) and default DeltaE showed luminance error.
- Fixed the Profile Analysis layout big CIE chart - wasn't showing the selected color.

18.0.0:
- Updated the Description layout.
- Replaced dE 2000 readings with dE ICtCp compensated (default) and with luminance error (indicated) in every layout with Delta E readings.
- New Meter Stability layout accessible from the Session Setup layout.
- Small chart upgrades to all the Calibration and Assessment layouts.
- Small chart upgrades to the Pre- and Post-Calibration Readings layouts.
- Corrected the Color Checker Full and Slim Datagrids.
- The usual small fixes and visual tweaks here and there, and who knows what else ...

Click here to download workflow
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 17.0.0
Requires CalMAN 5 release 5.9 or later.

- Removed the Dynamic Range Check layout and integrated it into the Session Setup layout to give better access to all possible affecting settings.
- Session Setup: Added meter profile configuration option.
- New meter profile analysis and maintenance layout accessible from Session Setup.
- Added DDC controls to the 2-point Grayscale Calibration layout.
- Slight restructure of the Multi-Point Grayscale Calibration layout.
- New CMS Gamut Calibration layout
- Reclassified Gamut Luminance and Color Checker from Calibration to Assessment layouts, since there is no AutoCal for them.
- Restructured the navigation bar in most layouts to account for removal of Dynamic Range and adding CMS Gamut Caliration layouts.
- Added ramp reading to Minimal 3D LUT Calibration layout.
- Some visual aesthetics tweaks here and there

Click here to download workflow
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 16.2.0
Requires CalMAN 5 release 5.6.1 or 5.7.2 or later, depending on version used. Use the latest possible for your license.

- FIXED: During the workflow category restructuring the links to the Post-Cal readings in the Final Check layout's Post-Cal Summary were broken (also fixed it in current 16.1 workflows in the previous versions section)
- Some delta-E groups observed luminance compensation while others didn't, now they all do. No impact on calibration accuracy but consistency is good.
- Added screen top convenience buttons to both Grayscale calibration layouts to switch between 2-point and multi-point
- The grayscale calibration nav bar buttons now will go to the last visited, 2-pt or multi-pt, instead of always going to the multi-point.
- Reworked the Multi-Point Grayscale Calibration layout, again (things ca always improve ...)
- Added the option to show / modify Setup layout display values in the Post-Cal Readings layout
- Fixed Post-Cal Grayscale Detail Chart avg. dE datafield
- Rearranged the single-point dE, Luminance & RGB charts in the Saturation Sweeps & Gamut Luminance Calibration layouts
- Returned the Delta C, H & L charts to the Gamut Luminance Calibration layout
- Some visual aesthetics tweaks here and there

Click here to download workflow for 5.7.2
Click here to download workflow for 5.6.1
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 16.1.0
Requires CalMAN 5 release 5.6.1 or 5.7.2 or later, depending the version used. You should use 5.7.2 if possible as the framework will be more up-to-date.

Updates from 16.0.0:
- NOTE: During the workflow category restructuring the links to the Post-Cal readings in the Final Check layout's Post-Cal Summary were broken in the original 16.1, but now fixed in these new previous versions ...
- Fixed the random chart corruption, mostly due to hidden DDC controls and old versions of charts
- Added LUT points to Post Calibration Readings layout
- Fixed HT Report source
- Added EOTF chart option to Multi-Point Grayscale Calibration
- Completely revised the Multi-Point Grayscale Calibration, no more simple multi-point
- Calibration datagrids are now inside the respective calibration layouts, not separate, except Color Checker which has some options
- Modified the Big Comparator option in the 3D LUT calibration layout
- Removed the hidden DCC controls from the Color Checker layout, added open CalMAN DDC panel button
- Changed the Saturation Sweeps and Gamut Luminance calibration layouts to have the DDC controls always visible
- Some chart changes to the Gamut Luminance calibration layout to avoid chart corruption
- Added EOTF chart to Pre/Post Grayscale detail charts, removing logarithmic luminance option
- Added hardware disconnect buttons & u'v' CIE chart option to Setup layout
- Added a u'v' CIE chart option to the color calibration layouts and for the Color Checker in the pre/pro calibration reading layouts (tailored for HDR)
- Some chart datafield corrections- More stuff I can't remember and the usual cosmetic tweaks

For 16.1.0:
- Newly created base framework
- Fixed transposed dE & luminance single point charts in Saturation Sweeps calibration layout
- Removed target lines from all charts - I find it less distracting and, oh yes, they would occasionally also cause chart corruption
- Tweaked and standardized the chart option selection mechanism for the Grayscale, Saturation Sweeps and Gamut Luminance calibration layouts
- Now have both absolute & relative big gamut luminance charts in the Gamut Luminance calibration layout
- Added big Y Luminance and Y Log Luminance chart options to the Gamut Luminance calibration layout
- Set the Gamut Luminance calibration layout's absolute luminance chart Y axis to a fixed settinge, to avoid it getting blasted by low blacks
- Added absolute & relative big gamut luminance charts to the Saturation Sweeps calibration layout
- Complete overhaul of the Grayscale Multi-Point calibration layout

Click here to download workflow for 5.7.2
Click here to download workflow for 5.6.1
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 15.2.1
Requires CalMAN 5 release 5.6 or later
Added a few convenience updates as well as being Calman 5.6 friendly instead of requiring 5.7:

- Added comparator option to Simple Grayscale calibration layout
- Target Black & White can now be set in either fL or cd/cm2 in Setup layout, nice for measuring unit comparison
- Fixed Home Theatre report sources
- Removed the Gamma Analysis layout as redundant with the current Grayscale Multipoint layout - you can always add another multi-point tab to experiment
- Added Contrast Ratio to the Grayscale Pre-/Post-Calibration Readings and Grayscale Pre-/Post-Calibration Analysis layouts
- Added luminance unit indicators to the Multi-Point Grayscale Calibration, Grayscale Pre-/Post-Calibration Readings and Grayscale Pre-/Post-Calibration Analysis layouts
- Minor cosmetic tweaks

Click here to download workflow
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 15.1.x
v15.1.x requires CalMAN v5.3.6, CalMAN v5.4.1, CalMAN v5.5.2or later depending on version
Though no real new calibration functionality has been added, this is a good visual / UI functional update.

- Added row, column and type settings to the Screen Uniformity layout
- Added new Gamma Analysis layout accessible from Setup and Multi-Point Grayscale layouts for trying out gamma related approaches
- Added Total Points and Giant CIE Chart option to Color Checker Calibration layout
- Added Virtual LUT indicator to 3D LUT Calibration layout
- Added more convenient return button to Pre/Post-Cal Color Checker Chart layouts
- Reconfigured Pre/Post-Cal Color Checker Chart layouts - removed the 2 notes, increased chart height and added comparator
- Added comparator to rest of Post-Cal Chart layouts
- Added buttons for swapping between full and simple / minimal calibration layouts
- Replaced the Nav Bar current step indicator from asterisk to a more intuitive red arrow shape
- Fine-tuned some Nav Bar titles and buttons

- Many other small fixes / tweaks

Click here to download workflow: This one requires CalMAN 5 release 5.5.2 or later, fixes two annoying cosmetic problems specific to 5.5.2, one in Color Checker and one in 3D Cube Calibration layouts
Click here to download workflow: This one requires CalMAN 5 release 5.4.0 or later
Click here to download workflow: This one requires CalMAN 5 release 5.3.6 or later (no enhanced session name or Color Checker custom color settings)
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 15.0.0
v15.0.0 requires CalMAN v5.3.6 or CalMAN v5.4.0 or later depending on version
This is a very significant update and I must say my favorite by far, visually and functionally. Main updates are Grayscale Calibration and Pre/Post-Calibration layouts, Home, Notes and Navigation Bar. Again also available for CalMAN 5.3 probably for the last time - too much work keeping two leveled versions :).

- Redid the overall Notes access approach: removed showing notes through a checked option on same layout, left the basic notes in the Setup, Pre/Post Cal Reading and Pre/Post Cal Color Checker Detail Charts, but without the Big option. Now the Notes button is in all layouts on bottom right (sometimes with one additional for convenience), and the Notes Management layout now has a Return button on bottom right that returns to the calling layout just like the Description layout does.

- Re-imagined the Home layout, hardly used but had fun re-thinking it, probably useful to first-time users, now also with Return button that goes back to the calling layout
- Added the black level to all grayscale & calibration layouts that did not already have it
- Standardized all Y Min & Y Max labels to "Black" and "White"
- Added average dE data field to all pre/post-calibration layouts
- Added datagrid to 2-Pt Grayscale Calibration layout

- Major rework of the Grayscale Calibration - Full layout: made the CIE zoom chart a toggled option with the RGB Relative Balance chart and with some juggling made charts taller with more resolution, data is better positioned for use while calibrating with DDC, removed the Minimal version as not saving anything

- Major rework of the Grayscale Pre/Post-Calibration Detail Charts layouts - removed the datagrid since there's been for a Pre/Post-Cal Datagrids layout, then reconfigured the other charts, added Log Y-axis option to Luminance chart, added an absolute RGB single-point chart

- Added Color Checker comparator to the Post-Cal Readings layout
- Restructured the 3D Color Cube LUT Calibration - Full layout: more concise and better high point count handling
- Major rework of the Navigation Bar button labels for a less busy look - I find them significantly easier to read now
- Updated the Help / Workflow Description layout
- Many other small fixes / tweaks

Click here to download workflow: This one requires CalMAN 5 release 5.4.0 or later
Click here to download workflow: This one requires CalMAN 5 release 5.3.6 or later (no enhanced session name or Color Checker custom color settings)
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 14.0.0
v14.0.0 requires CalMAN v5.3.6 or CalMAN v5.4.0 or later depending on version
This is a significant update especially in the Pre- and Post-Calibration Reading layouts, and complies with some 5.4 recommendations.

- Session Setup: Added Start New Session button, editable session name (not in 5.3.6)
- Pre- and Post-Calibration Readings: significant makeover - removed clumped view read buttons and properties and moved them to specific view sections, found it's more intuitive by their specific chart, added read all & stop button in mid-screen, display-only session name (not in 5.3.6)
- Added "Back to Readings" buttons to the individual Pre- and Post-Cal detail charts for convenient flipping between readings and detail charts
- Added Color Checker Custom Color Set selection dropdown and "use me" checkmark to Color Checker Calibration, Pre- and Post-Cal Readings layouts (not in 5.3.6)
- Tweaked Color Checker CIE charts in all applicable layouts for better handling the full points complement
- 3D Color Cube Calibration: removed zoomed chart as recommended for the new 5.4 CalMAN implementation and tweaked layout accordingly, some tweaks for large number LUTs
- Final Check layout: Added editable session name (not in 5.3.6)
- Some additional Nav Bar button tweaks
- Small fixes / tweaks

Click here to download workflow: This one requires CalMAN 5 release 5.4.0 or later
Click here to download workflow: This one requires CalMAN 5 release 5.3.6 or later (no enhanced session name or Color Checker custom color settings)
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 13.0.0
v13.0.0 requires CalMAN 5 release 5.3.6 or later
This is a significant update including some alternate simple / minimal calibration layouts with matching data layouts for hopefully faster AutoCal, improved nav bar navigation in the data world, tons of visual fine tuning many of which are probably not very noticeable to most users but they look nice to me :)

- Home and Description layouts: updated with the latest workflow changes and a visual makeover
- Multi-Point Grayscale Calibration: improved the Full layout, simplified the Simple layout and added new Minimal layout, each with corresponding datagrid layouts
- Color Checker Calibration: CIE charts for larger color sets, added buttons to open/close settings panel for easier change of color sets
- 3D Color Cube LUT Calibration: improved the Full layout, added new alternate Minimal layout with no charts, each with corresponding datagrid layouts
- Pre- and Post-Calibration Readings layouts: added button in the Color Checker configuration section to open settings panel for easier change of color sets
- Color Checker Pre- and Post-Calibration Detail layouts: made the CIE charts larger
- Calibration Datagrids: enhanced the buttons for convenience & standardization
- Final Check: updated to allow selection of 3D LUT data from Full or Minimal layouts
- Nav Bar: added Workflow Help button at the top in every layout to show Description layout with corresponding return button to initiating layout, updated the nav bar to account for calibration & data grid changes, fine tuned the special button graphics to better conform the standard button look
- Many small fixes / tweaks

Click here to download workflow
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 12.0.0
v12.0.0 requires CalMAN v5.2.2 or later
This is a significant update especially for the the Multi-Point Grayscale and Setup layouts.

- Rebuilt core framework from scratch - last clean build was many revisions ago, hopefully streamlines the core from all the adding / removing controls & features
- Setup layout: removed calibration selection feature, not really that useful and originally an exercise to try conditional code feature, optimized session option control placement
- Multi-Point Grayscale Calibration: new improved full layout, added new alternate simplified layout with no options
- Updated the Home and Description layouts with the latest workflow changes
- Updated the navigation bar to account for layout changes
- Various small fixes / tweaks

Click here to download workflow
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 11.2.0
v11.2.0 requires CalMAN v5.2.2 or later
This is a more significant update especially for the the Multi-Point Grayscale and Color Checker Calibration layouts.

- Multi-Point Grayscale Calibration: significant makeover, charts are horizontal again, added RGB balance line chart, luminance chart has logarithmic Y axis option; removed Big Picture as not needed
- Color Checker Calibration: significant makeover, added summary section
- 3D Cube LUT Calibration: added summary section; the 2 reference color bars that appeared in the multi-point dE chart automatically before now are controlled by a manual checked option
- Saturation Sweeps & Gamut Luminace Calibration: added summary section
- Pre/Post Cal Reading: button makeover
- Navbar theme makeover
- Various small fixes

Click here to download workflow
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 11.1.0
v11.1.0 requires CalMAN v5.2.2 or later
This is a mostly visual minor update but I find the better readability in the Multi-Point Grayscale Calibration layout is helpful, or if you run a gazillion points in the Color Checker Calibration layout ...

- Multi-Point Grayscale Calibration: removed some repeated data (didn't really help) and some grouping and highlighting for readability
- Color Checker Calibration: added a new selectable option for a slim data set in the Calibration Datagrid, split into 2 tabs to speed up large number of color points - you can always modify the displayed data elements without going to design mode, and optimized (I like it better!) the position of the Comparator
- Made the "Data" button labels in the calibration section of the nav bar layout-specific rather than generic "Data" (only the new Multi-Point Grayscale & Color Checker calibration layout images here show this - got lazy but you get the picture (some :-))

Click here to download workflow
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 11.0.0
v11.0.0 requires CalMAN v5.2.2 or later
This is a major update especially from a visual standpoint. Some color has been added, hopefully more focusing than distracting - it may take some getting used to. Let me know if it strikes the wrong chord for you. Here are the major areas.

- Implemented the motto "To calibrate good you need to look good!"
- Revised workflow description / help
- Removed many annoyingly obvious and sometimes wrong button tool tips
- More consistent text color coding
- Removed the less effective duplicate buttons
- Gave the Navigation Bar a visual makeover and is now present in every layout (pretty much), and some special buttons with color coding matching the layout zones
- Improved DDC panel configurations
- Saturation & Luminance Calibration layouts: Complete make-over; comparator setup reconfigures based on points, fixed the Delta H Max & Avg which did not match the chart because of luminance compensation
- Grayscale Calibration layout: Complete make-over (may take some getting used to), new Big Picture tab for high-level inspection and correlation
- Saturation & Luminance Pre- and Post- Analysis Detail Charts: Fixed the Delta H Max & selected did not match the chart because of luminance compensation
- Session Setup layout: Some rearranging, moved lum unit to less obscure option area, fixed DDC spelling (?!)
- Added RGB cuts & gains settings to Pre-Cal & Post-Cal Readings, Final Check
- New efficient and expanded notes configuration in the Setup, various Calibration and the Final Check layouts, and a new comprehensive Notes Management layout with all available notes in one place
- 3D Color Cube LUT calibration layout: significant make-over, comparator setup reconfigures based on points, better point measurement charts and some chart reconfigurations to better handle mega-point cube datasets
- Many visual tweaks in the small details for the titles, option controls and such which you may or may not notice

Click here to download workflow
Click here to display or download screens as a PDF book

-------------------------------------
Previous version 10.1.0
v10.1.0 requires CalMAN v5.2 or later
Completely replaces 10.0 because the Color Checker Calibration Layout in 10.0 was not up to snuff when Black was enabled, never mind schemas with more colors.

- Grayscale calibration layouts: corrected the single small chart to auto-scale
- Color Checker calibration layout: completely redesigned to make the charts friendly with high point counts - the previous one was pretty bad unless you had the classic colors without Black.
- 3D Color Cube LUT calibration layout: moved some detail data to make it less congested

From v10.0:
This is a substantial update especially the calibration layouts and all the 3D Color Cube LUT layouts. The only layouts untouched were the three analysis datagrids. Key goals were readability and consistency, and taking advantage of new features

- Removed extra navigation buttons that weren't really useful and cluttered the landscape
- Navigation Bar: streamlined the look
- Setup layout: Completely revised the layout composition and updated the target gamma field to show 2 decimals
- Calibration layouts: mayor revisions for better readability and graphic info, added triplet data, option selectors in more consistent locations, all sliders now useable with extreme point counts
- Grayscale calibration layout: added notes, gamma level single, contrast ratio
- Color Checker calibration layout: now includes both HSL and RGB DDC controls
- 3D Color Cube LUT calibration layout: added LUT selection, ramp selectors, dE and dL single graphs. Ramp reading is broken in CalMAN 5.2 but fixed when 5.2.1 is released. Also analysis chart meter buttons cannot currently read the calibration layout so charts do not change using them.
- Pre- and Post-Calibration Reading layouts: some reconfiguration, added Y min (black) display to the grayscale section
- Final Check layout : major redesign with a more complete post-calibration results summary, contrast ratio
- Several nav button and other bugs fixed

Click here to download workflow
Click here to display or download screens as a PDF book